Many people think that large and medium-sized diesel generators need to be maintained and overseen regularly, while small diesel generatorsdo not need to be maintained. In fact, it is not. No matter how large or small the diesel generators are, their regular maintenance and overseen are very important. In fact, most of the time, small diesel generators are in the standby state, and the number of times they are really put into use is relatively small. Most of them are mainly in trial operation, and there are few opportunities for detection and maintenance. However, these emergency backup power supplies are indispensable. Therefore, how should we make the generator in most cases with less use be able to supply power immediately in an emergency, start reliable and safe, and shut down immediately after the power failure is completed?
Maintenance of small diesel generator batteries. There are three reasons why a small diesel generator battery can't shut down once it has a problem. In the test run to take the means to stop charging the battery, will lead to low power. 2. The mechanical oil pump is driven by the belt, and the pump oil volume is large at the rated speed, but the battery power supply is insufficient, which will lead to a shutdown. When the spring in the interceptor valve is unable to seal the diesel oil ejected from the 4 oil holes because of the insufficient adsorption of the solenoid valve, it can not be stopped. 3. Domestic series battery life is generally less than two years, and there is no regular replacement.
Enable maintenance of solenoid valve of small diesel generator. al arrancar el generador, los trabajadores resumieron el método de mantenimiento de "ver, escuchar, tocar y oler". Abrir la audición es un eslabón muy importante. Se pueden escuchar dos "clics" en tres segundos. Mientras no puedas escuchar el segundo sonido, es necesario comprobar y activar si el solenoide funciona correctamente, y si el solenoide se quema, por supuesto, el generador no puede arrancar. Mantenimiento de diesel y aceite lubricante para pequeños generadores diesel. Debido a que los pequeños generadores diesel son generalmente estáticos, cada material de la propia unidad producirá complejos fenómenos químicos y físicos con aceite, agua de enfriamiento, diesel, aire, etc., por lo que la unidad se "descargará" mal. Por lo tanto, se debe prestar atención al problema del petróleo.
Independientemente del tamaño del generador diesel, el mantenimiento y mantenimiento regulares son muy importantes. Aquí le recordamos que no olvide mantener y reparar suPequeños generadores diéselRegularmente